Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester

Large Image :  Fast Insulation Resistance Test Equipment Double Clamp On Ground Resistance Tester Get Best Price

Product Details:
Place of Origin: China
Brand Name: Fanke High-Voltage
Certification: ISO9001
Model Number: UT 575A
Payment & Shipping Terms:
Minimum Order Quantity: One unit
Price: Negotiable
Packaging Details: Export standard wooden case with fumigation free
Delivery Time: 10 work days
Payment Terms: T/T
Supply Ability: 10units/month
Detailed Product Description
Usage: Grounding Resistance Test , Soil Resistivity Test , DC Resistance Test Test Method: 2/3/4-wire Measurements
Measurement Range: Ground Resistance Range0.01Ω~30.00kΩ Feature: With Double Clamp Test, Large-diameter Current Clamp Design
Diameter Of Current Clamp: 50mm Meet Standard: IEC60101-1; IEC61010-2-31; IEC61557-1,5
Name: Soil Resistivity Testing Equipment
High Light:

high voltage insulation resistance tester

,

ground resistance test equipment

Double Clamp Multi-function Grounding Resistance Tester , Soil Resistivity Tester , DC Resistance Tester
 
I. Product Introduction :
 
The UT575A grounding resistance tester is microprocessor controlled to accurately detect ground resistance, soil resistivity, ground voltage, DC resistance and AC current. The same screen shows the resistance value of the auxiliary electrode, which is convenient for judging the measurement error caused by environmental factors, and it is convenient to measure the true resistance value of the grounding resistance more accurately. At the same time, 500 sets of data can be stored, and the monitoring software can monitor the data online. The USB data is uploaded to the PC and has unique functions such as numerical maintenance and intelligent alarm prompts.
The measurement usage of the tester inludes as following:

1. 2/3/4-pole measurement Ground Resistance, Ground Resistance range0.01Ω~30.00kΩ

2. Selection method, double clamp method to measure the grounding resistance

3. Soil Resistivity 0.01Ωm~9999kΩm

4. Ground Voltage 0.1V~100.0V

5. AC current leakage current measurement 0.01mA~1000A

 
II. Main Features 
 
1. Large-diameter current clamp design for measuring any grounding resistance of complex grounding conditions such as single point and mesh grounding;
2. Precision 4-wire method, 3-wire method and simple 2-line method, selection method, double-clamp method measurement;
3. Fast filtering technology, with excellent anti-interference ability and environmental adaptability, repeated test consistency, ensuring measurement accuracy, stability and reliability.
4. Data storage function for 500 sets of data storage;
5. Upload to PC via USB data cable for display analysis and output test report
 
III. Main Technical Data  

 

Measurement functions Measurement range Accuracy Resolution
2/3/4-wire methods for grounding resistance measurement(Re) 0.00Ω~29.99Ω ±2%rdg±5dgt 0.01Ω
30.0Ω~299.9Ω ±2%edg±3dgt 0.1Ω
300Ω~2999Ω
3.00kΩ~30.00kΩ 10Ω
DC resistance(R-) 0.00Ω~299.9Ω ±2%edg±3dgt 0.1Ω
300Ω~2999Ω
3.00kΩ~30.00kΩ 10Ω
Selection method for grounding resistance measurement(Re) 0.00Ω~29.99Ω ±2%rdg±5dgt 0.01Ω
30.0Ω~299.9Ω ±2%edg±3dgt 0.1Ω
300Ω~3000Ω
Double clamp method for grounding resistance measurement(Re) 0.01Ω~0.99Ω ±10%rdg±10dgt 0.01Ω
1.0Ω~9.9Ω 0.1Ω
10Ω~100Ω
Soil Resistivity(ρ) 0.00Ωm~99.99Ωm ρ=2πaR 0.01Ωm
100.0Ωm~999.9Ωm 0.1Ωm
1000Ωm~9999Ωm 1Ωm
10.00kΩm~99.99kΩm 10Ωm
100.0kΩm~999.9kΩm 100Ωm
1000kΩm~9999kΩm 1kΩm
Grounding voltage 0.00~100.0V ±2%rdg±3dgt 0.01V
AC Current 0.0mA~1000A ±2%rdg±3dgt 0.1mA
Basic functions
Measurement method Precision 4-wire method, 3-wire method and simple 2-line method, selection method, double-clamp method measurement for grounding resistance
Display mode 4-digit LCD display
Data storage 500 groups
Data communication USB interface
Measurement time 2time/second
Overload display
Overload protection
Alarm functions
Auto shut-down
Under-voltage indication
Backlight function
Power supply DC 6V 4.5ah lead-acid battery Continuous standby for more than 100 hours
Safety level CAT III 300V
Standard accessories 4pcs of grounding probes, 2pcs of current clamps , 1 software disk, 1 communication cable, 4pcs of testing wires, 2pcs of simple testing wires, 1charger 1 6v battery ,1 manual and quality certificate, 1 storage bag

 